The effect of bispectral index monitoring on cognitive performance following sedation for outpatient colonoscopy
a randomized controlled trial
Keywords:
Consciousness monitors, Cognition, Conscious sedation, ColonoscopyAbstract
BACKGROUND: Bispectral index (BIS) monitoring can positively affect cognitive performance through decreasing the use of sedative agents. We aimed to evaluate the effect of BIS monitoring on early cognitive performance among patients undergoing sedation for colonoscopy. DESIGN AND SETTING: Randomized, controlled trial in a university hospital. METHODS: 100 patients were randomized into two groups. In the monitored group (n = 50), the depth of anesthesia was monitored using the BIS, and BIS scores were maintained between 60 and 80. In the usual care group (n = 50), BIS monitoring was not performed. To determine the patients’ baseline cognitive per-formance levels, the mini-mental state examination (MMSE), Trieger dot test (TDT) and clock drawing test (CDT) were used. The patients’ post-procedure cognitive performance levels were determined when they were classified as ready for discharge. RESULTS: The total volume (mg) of propofol used [median (range) IQR] in the sedation procedure was lower in the monitored group [100 (50-200) 100-140] than in the usual care group [150 (75-200) 100-200] (P < 0.001). The discharge scores [mean (SD)] using MMSE and CDT were higher in the monitored group [26 (3) and 3 (1), respectively] than in the usual care group [23 (3) and 2 (1), respectively] (P = 0.002 and P = 0.002, respectively). The discharge scores using TDT [mean (SD)] were lower in the monitored group [11 (7)] than in the usual care group [15 (11)] (P = 0.033). CONCLUSION: BIS monitoring among sedated patients was associated with lower propofol use and smaller decline in cognitive performance. CLINICAL TRIAL REGISTRATION: This trial was registered in the Australian New Zealand Clinical Trial Reg-istry (ACTRN12617000134325).
Downloads
References
Padmanabhan U, Leslie K, Eer AS, Maruff P, Silbert BS. Early cognitive impairment after sedation for colonoscopy: the effect of adding midazolam and/or fentanyl to propofol. Anesth Analg. 2009;109(5):1448‑55. PMID: 19617584; doi: 10.1213/ane.0b013e3181a6ad31.
von Delius S, Thies P, Rieder T, et al. Auditory evoked potentials compared with bispectral index for monitoring of midazolam and propofol sedation during colonoscopy. Am J Gastroenterol. 2009;104(2):318‑25. PMID: 19190608; doi: 10.1038/ajg.2008.73.
Sauër AM, Kalkman C, van Dijk D. Postoperative cognitive decline. J Anesth. 2009;23(2):256-9. PMID: 19444566; doi: 10.1007/s00540-009‑0744-5.
Krenk L, Rasmussen LS, Kehlet H. New insights into the pathophysiology of postoperative cognitive dysfunction. Acta Anaesthesiol Scand. 2010;54(8):951-6. PMID: 20626359; doi: 10.1111/j.1399-6576.2010.02268.x.
Rasmussen LS, Larsen K, Houx P, et al. The assessment of postoperative cognitive function. Acta Anaesthesiol Scand. 2001;45(3):275-89. PMID: 11207462; doi: 10.1034/j.1399-6576.2001.045003275.x.
Rörtgen D, Kloos J, Fries M, et al. Comparison of early cognitive function and recovery after desflurane or sevoflurane anaesthesia in the elderly: a double-blinded randomized controlled trial. Br J Anaesth. 2010;104(2):167-74. PMID: 20042477; doi: 10.1093/bja/aep369.
Silverstein JH, Steinmetz J, Reichenberg A, Harvey PD, Rasmussen LS. Postoperative cognitive dysfunction in patients with preoperative cognitive impairment: which domains are most vulnerable? Anesthesiology. 2007;106(3):431-5. PMID: 17325500.
Steinmetz J, Rasmussen LS. Cognitive deterioration after surgery. Ugeskr Laeger. 2008;170(49):4032-4. PMID: 19087744.
Wu CL, Hsu W, Richman JM, Raja SN. Postoperative cognitive function as an outcome of regional anesthesia and analgesia. Reg Anesth Pain Med. 2004;29(3):257-68. PMID: 15138912.
Medical Advisory Secretariat. Bispectral index monitor: an evidence-based analysis. Ont Health Technol Assess Ser. 2004;4(9):1-70. PMID: 23074459.
Johansen JW. Update on bispectral index monitoring. Best Pract Res Clin Anaesthesiol. 2006;20(1):81-99. PMID: 16634416.
Paspatis GA, Chainaki I, Manolaraki MM, et al. Efficacy of bispectral index monitoring as an adjunct to propofol deep sedation for ERCP: a randomized controlled trial. Endoscopy. 2009;41(12):1046-51. PMID: 19967620; doi: 10.1055/s-0029-1215342.
Imagawa A, Fujiki S, Kawahara Y, et al. Satisfaction with bispectral index monitoring of propofol-mediated sedation during endoscopic submucosal dissection: a prospective, randomized study. Endoscopy. 2008;40(11):905-9. PMID: 19023932; doi: 10.1055/s-2008-1077641.
Chen SC, Rex DK. An initial investigation of bispectral monitoring as an adjunct to nurse administered propofol sedation for colonoscopy. Am J Gastroenterol. 2004;99(6):1081-6. PMID: 15180729.
Drake LM, Chen SC, Rex DK. Efficacy of bispectral monitoring as an adjunct to nurse-administered propofol sedation for colonoscopy: a randomized controlled trial. Am J Gastroenterol. 2006;101(9):2003-7. PMID: 16968506; doi: 10.1111/j.1572-0241.2006.00806.x.
Yu YH, Han DS, Kim HS, et al. Efficacy of bispectral index monitoring during balanced propofol sedation for colonoscopy: a prospective, randomized controlled trial. Dig Dis Sci. 2013;58(12):3576-83. PMID: 23982208; doi: 10.1007/s10620-013-2833-4.
Farag E, Chelune GJ, Schubert A, Mascha EJ. Is depth of anesthesia, as assessed by the Bispectral Index, related to postoperative cognitive dysfunction and recovery? Anesth Analg. 2006;103(3):633-40. PMID: 16931673; doi: 10.1213/01.ane.0000228870.48028.b5.
Ulusoy H, Coskun I, Arslan M. Effects of midazolam or tramadol premedication on early cognitive function in endoscopic retrograde cholangiopancreatography (ERCP): A randomized, controlled, double-blind study. J Int Med Res. 2016;44(3):542-56. PMID: 26944385; doi: 10.1177/0300060515600189.
Leslie K, Myles PS, Chan MT, et al. Risk factors for severe postoperative nausea and vomiting in a randomized trial of nitrous oxide-based vs nitrous oxide-free anaesthesia. Br J Anaesth. 2008;101(4):498-505. PMID: 18682411; doi: 10.1093/bja/aen230.
Leslie K, Myles PS, Forbes A, et al. Recovery from bispectral index-guided anaesthesia in a large randomized controlled trial of patients at high risk of awareness. Anaesth Intensive Care. 2005;33(4):443-51. PMID: 16119484.
Quesada N, Júdez D, Martínez Ubieto J, et al. Bispectral Index Monitoring Reduces the Dosage of Propofol and Adverse Events in Sedation for Endobronchial Ultrasound. Respiration. 2016;92(3):166-75. PMID: 27598398; doi: 10.1159/000448433.
Cohen LB, Delegge MH, Aisenberg J, et al. AGA Institute review of endoscopic sedation. Gastroenterology. 2007;133(2):675-701. PMID: 17681185; doi: 10.1053/j.gastro.2007.06.002.
Folstein MF, Folstein SE, McHugh PR. “Mini-mental state”. A practical method for grading the cognitive state of patients for the clinician. J Psychiatr Res. 1975;12(3):189-98. PMID: 1202204; doi: 10.1016/0022-3956(75)90026-6.
Newman MG, Trieger N, Miller JC. Measuring recovery from anesthesia--a simple test. Anesth Analg 1969;48(1):136-40. PMID: 5812547.
Freedman MI, Leach L, Kaplan E, et al. Clock Drawing. Oxford: Oxford University Press; 1994.
Chung F. El proceso del alta. Anestesia ambulatoria de Twersky RS. Madrid: Mosby/Doyma libros; 1996. p. 457-75.
Kermany MP, Soltani MH, Ahmadi K, et al. The impact of anesthetic techniques on cognitive functions after urological surgery. Middle East J Anaesthesiol. 2015;23(1):35-42. PMID: 26121893.
Chan MT, Gin T. What does the bispectral EEG index monitor? Eur J Anaesthesiol. 2000;17(3):146-8. PMID: 10758461; doi: 10.1046/j.1365-2346.2000.00613.x.
Liu SS. Effects of Bispectral Index monitoring on ambulatory anesthesia: a meta-analysis of randomized controlled trials and a cost analysis. Anesthesiology. 2004;101(2):311-5. PMID: 15277912.
Punjasawadwong Y, Boonjeungmonkol N, Phongchiewboon A. Bispectral index for improving anaesthetic delivery and postoperative recovery. Cochrane Database Syst Rev. 2007;(4):CD003843. PMID: 17943802; doi: 10.1002/14651858.CD003843.pub2.
Heo J, Jung MK, Lee HS, et al. Effects of bispectral index monitoring as an adjunct to nurse-administered propofol combined sedation during colonoscopy: a randomized clinical trial. Korean J Intern Med. 2016;31(2):260-6. PMID: 26932401; doi: 10.3904/kjim.2014.077.
Radtke FM, Franck M, Lendner J, et al. Monitoring depth of anaesthesia in a randomized trial decreases the rate of postoperative delirium but not postoperative cognitive dysfunction. Br J Anaesth. 2013;110 Suppl 1:i98-105. PMID: 23539235; doi: 10.1093/bja/aet055.
Chan MT, Cheng BC, Lee TM, Gin T; CODA Trial Group. BIS-guided anesthesia decreases postoperative delirium and cognitive decline. J Neurosurg Anesthesiol. 2013;25(1):33-42. PMID: 23027226; doi: 10.1097/ ANA.0b013e3182712fba.