Hemorrhagic shock secondary to button battery ingestion
Keywords:
Foreign bodies, Electric power supplies, Gastrointestinal hemorrhage, Shock, ChildAbstract
CONTEXT: Button battery ingestion is a frequent pediatric complaint. The serious complications resulting from accidental ingestion have increased significantly over the last two decades due to easy access to gadgets and electronic toys. Over recent years, the increasing use of lithium batteries of diameter 20 mm has brought new challenges, because these are more detrimental to the mucosa, compared with other types, with high morbidity and mortality. The clinical complaints, which are often nonspecific, may lead to delayed diagnosis, thereby increasing the risk of severe complications. CASE REPORT: A five-year-old boy who had been complaining of abdominal pain for ten days, was brought to the emergency service with a clinical condition of hematemesis that started two hours earlier. On admission, he presented pallor, tachycardia and hypotension. A plain abdominal x-ray produced an image suggestive of a button battery. Digestive endoscopy showed a deep ulcerated lesion in the esophagus without active bleeding. After this procedure, the patient presented profuse hematemesis and severe hypotension, followed by cardiorespiratory arrest, which was reversed. He then underwent emergency exploratory laparotomy and presented a new episode of cardiorespiratory arrest, which he did not survive. The battery was removed through rectal exploration. CONCLUSION: This case describes a fatal evolution of button battery ingestion with late diagnosis and severe associated injury of the digestive mucosa. A high level of clinical suspicion is essential for preventing this evolution. Preventive strategies are required, as well as health education, with warnings to parents, caregivers and healthcare professionals.
Downloads
References
Martins CB, Andrade SM. Acidentes com corpo estranho em menores de 15 anos: análise epidemiológica dos atendimentos em pronto- socorro, internacções e óbitos [Accidents with foreign bodies in children under 15 years of age: epidemiological analysis of first aid services, hospitalizations, and deaths]. Cad Saude Publica. 2008;24(9):1983-90.
Baracat ECE, Paraschin K, Nogueira RJN, et al. Acidentes com crianças e sua evolução na região de Campinas, SP [Accidents with children in the region of Campinas, Brazil]. J Pediatr (Rio J). 2000;76(5):368-74.
Ospina Nieto J, Posada Castrillón ME. Cuerpos estrãnos en tracto gastrointestinal en niños [Foreign bodies in gastrointestinal tract in children]. Rev Colomb Gastroenterol. 2008;23(3):233-8.
Yardeni D, Yardeni H, Coran AG, Golladay ES. Severe esophageal damage due to button battery ingestion: can it be prevented? Pediatr Surg Int. 2004;20(7):496-501.
Litovitz T, Schmitz BF. Ingestion of cylindrical and button batteries: an analysis of 2382 cases. Pediatrics. 1992;89(4 Pt 2):747-57.
Litovitz T, Whitaker N, Clark L. Preventing battery ingestions: an analysis of 8648 cases. Pediatrics. 2010;125(6):1178-83.
Chang YJ, Chao HC, Kong MS, Lai MW. Clinical analysis of disc battery ingestion in children. Chang Gung Med J. 2004;27(9):673-7.
Centers for Disease Control and Prevention (CDC). Injuries from batteries among children aged < 13 years--United States, 1995-2010. MMWR Morb Mortal Wkly Rep. 2012;61(34):661-6.
Soccorso G, Grossman O, Martinelli M, et al. 20 mm lithium button battery causing an oesophageal perforation in a toddler: lessons in diagnosis and treatment. Arch Dis Child. 2012;97(8):746-7.
Tanigawa T, Shibata R, Katahira N, Ueda H. Battery ingestion: the importance of careful radiographic assessment. Intern Med. 2012;51(18):2663-4.
Tan A, Wolfram S, Birmingham M, et al. Neck pain and stiffness in a toddler with history of button battery ingestion. J Emerg Med. 2011;41(2):157-160.
Sudhakar PJ, Al Dossary J, Malik N. Spondylodiscitis complicated by the ingestion of a button battery: a case report. Korean J Radiol. 2008;9(6):555-8.
Harjai MM, Ramalingam W, Chitkara G, Katiyar A. Corrosive tracheo- esophageal fistula following button battery ingestion. Indian Pediatr. 2012;49(2):145-6.
Mortensen A, Hansen NF, Schiødt OM. Fatal aortoesophageal fistula caused by button battery ingestion in a 1-year-old child. Am J Emerg Med. 2010;28(8):984.e5-6.
Jarugula R, Dorofaeff T. Oesophageal button battery injuries: think again. Emerg Med Australas. 2011;23(2):220-3.
Ozokutan BH, Ceylan H, Yapici S, Simsik S. Perforation of Meckel’s diverticulum by a button battery: report of two cases. Ulus Travma Acil Cerrahi Derg. 2012;18(4):358-60.
Imamoğlu M, Cay A, Koşucu P, Ahmetoğlu A, Sarihan H. Acquired tracheo-esophageal fistulas caused by button battery lodged in the esophagus. Pediatr Surg Int. 2004;20(4):292-4.
Bernstein JM, Burrows SA, Saunders MW. Lodged oesophageal button battery masquerading as a coin: an unusual cause of bilateral vocal cord paralysis. Emerg Med J. 2007;24(3):e15.
Gordon AC, Gough MH. Oesophageal perforation after button battery ingestion. Ann R Coll Surg Engl. 1993;75(5):362-4.
Grisel JJ, Richter GT, Casper KA, Thompson DM. Acquired tracheoesophageal fistula following disc-battery ingestion: can we watch and wait? Int J Pediatr Otorhinolaryngol. 2008;72(5):699-706.
Takagaki K, Perito ER, Jose FA, Heyman MB. Gastric mucosal damage from ingestion of 3 button cell batteries. J Pediatr Gastroenterol Nutr. 2011;53(2):222-3.
Marom T, Goldfarb A, Russo E, Roth Y. Battery ingestion in children. Int J Pediatr Otorhinolaryngol. 2010;74(8):849-54.
Sharpe SJ, Rochette LM, Smith GA. Pediatric battery-related emergency department visits in the United States, 1990-2009. Pediatrics. 2012;129(6):1111-7.
Kimball SJ, Park AH, Rollins MD 2nd, Grimmer JF, Muntz H. A review of esophageal disc battery ingestions and a protocol for management. Arch Otolaryngol Head Neck Surg. 2010;136(9):866-71.
Litovitz T, Whitaker N, Clark L, White NC, Marsolek M. Emerging battery-ingestion hazard: clinical implications. Pediatrics. 2010; 125(6):1168-77.
Chung S, Forte V, Campisi P. A review of pediatric foreign body ingestion and management. Clinical Pediatric Emergency Medicine. 2010;11(3):225-30. Available from: http://www.clinpedemergencymed.com/article/S1522-8401(10)00040-6/abstract. Accessed in 2013 (Aug 20).
Blatnik DS, Toohill RJ, Lehman RH. Fatal complication from an alkaline battery foreign body in the esophagus. Ann Otol Rhinol Laryngol. 1977;86(5 Pt 1):611-5.
Brumbaugh DE, Colson SB, Sandoval JA, et al. Management of button battery-induced hemorrhage in children. J Pediatr Gastroenterol Nutr. 2011;52(5):585-9.
Tanaka J, Yamashita M, Yamashita M, Kajigaya H. Esophageal electrochemical burns due to button type lithium batteries in dogs. Vet Hum Toxicol. 1998;40(4):193-6.